HAMILTON-C1

Minimum size for maximum performance:

  • Adult, pediatric, and neonatal ventilation
  • 4 h of battery operating time
  • Independence from gas cylinders or compressors
  • Integrated high flow oxygen therapy
  • Noninvasive ventilation
24
7
SUPPORT

Requiring only a minimum of space, the HAMILTON-C1 combines invasive and noninvasive modes as well as high flow oxygen therapy with maximum mobility. This makes it an ideal companion for all patient groups in the intensive care unit, emergency ward, recovery room or intermediate care, long-term acute care facilities, and during intrahospital transport. The integrated high-performance turbine enables the HAMILTON-C1 to be completely independent from compressed air. In addition, it provides a peak flow rate of up to 260 l/min, guaranteeing optimal performance even in noninvasive ventilation. The HAMILTON-C1 includes Hamilton Medical's standardized Ventilation Cockpit user interface and the unique intelligent ventilation mode, Adaptive Support Ventilation® (ASV®).

The HAMILTON-C1 offers:

  • Adult, pediatric and neonatal ventilation
  • Independence from air supply with integrated ultra-quiet turbine (up to 260l/m for adult/pediatric and up to 40l/m for neonates)
  • O2 supply either from high or low O2 source
  • Minimum size and weight of less than 5 kg
  • Over 4 hours of battery operating time
  • Intelligent automated ventilation via Adaptive Support Ventilation (ASV)
  • Advanced invasive ventilation modes such as (S)CMV+, SIMV+, PCV+, PSIMV+ & SPONT
  • Synchronized non - invasive ventilation modes such as NIV & NIV-ST (optional)
  • Bilevel ventilation modes such as DuoPAP & APRV(optional)
  • Demand-flow nCPAP & nCPAP-PC ventilation modes (optional)
  • High flow oxygen therapy (optional)
  • Automatic response (leak compensation) to varying leaks and adaption of trigger sensitivity in all modes by IntelliTrig
  • Guaranteed rate ventilation by PSync
  • 4 in, TFT color, backlit, touch screen display
  • Display of more than 50 monitoring parameters
  • Visual representation of ventilator dependency and weaning process, grouped into oxygenation, CO2 elimination, patient activity, via Vent Status
  • Real-time visualization of the lungs with representations of tidal volume, lung compliance, resistance, and patient activity via Dynamic lung
  • Graphic display of target and actual parameters for tidal volume, frequency, pressure, patient activity, and minute ventilation via ASV target graphics
  • Real-time waveforms for Paw, Flow, Volume, CΟ2 (optional) & SpO2 (optional)
  • Loops P-V, V-Flow, P-Flow, V-CO2 & trends up to 72 hours (optional)
  • Storage and display of up to 1,000 events with date and time via Event log
  • Volumetric mainstream capnography, sidestream capnography (optional)
  • SpO2 measurement (optional)
  • Compatibility of the pressure controlled modes (PCV+, PSIMV+, SPONT) with speaking valves via SpeakValve function (optional)
  • Various interface connections such as USB, RS-232, nurse call(optional), CO2 (optional), SPO2 (optional)
  • Trolley with Humidifier support, cylinder holder
  • Tubing support arm
  • Standards: IEC 60601-1, IEC 60601-1-2, ISO 80601-2-12, CAN/CSA-C22.2 No. 60601-1, ES60601-1

HAMILTON-C1