espa2
espa
English
BACK TO PRODUCTS
ME MB 3 ENDO
MANUFACTURER : KLS MARTIN
PRODUCT CATEGORY :
As evidenced by its ergonomic handling, the ME MB3 utilizes proven technology. Special rotary switches are provided to set the power individually for each operating mode, with the settings indicated on a digital display.  
DETAILED DESCRIPTION
TECHNICAL SPECIFICATIONS
ACCESSORIES
RELATED FILES
VIDEO

As evidenced by its ergonomic handling, the ME MB 3 utilizes proven technology. Special rotary switches are provided to set the power individually for each operating mode, with the settings indicated on a digital display. The appropriate types of current can be selected easily via dedicated buttons arranged on the membrane keyboard.

  • Power requirements: 220–240 V, 50–60 Hz; or 100–127 V, 50–60 Hz (adjustable by Technical Service via plug-in jumper inside  unit)
  • Power input:
  • without HF output: approx. 26 VA
  • at max. power output: approx. 800 VA
  • Protection class: I
  • Classification acc. to MDD: II b
  • Leakage currents: LF and HF in compliance with IEC 601, Part 2-2
  • Type: CF; defibrillation-proof
  • Nominal frequency: 450 kHz
  • Modulation frequency: 30 kHz

HF OUTPUT POWER:

Type of current

  • Cut 1 (pure)
    • Power: max. 400 W at 300 Ω
    • Crest factor: 6 at 300 Ω
    • Voltage: max. 2,300 Vpp
  • Cut 2 (blend)
    • Power: max. 300 W at 300 Ω
    • Crest factor: 1.9 at 300 Ω
    • Voltage: 2,500 Vpp
  • Cut 3 (super blend)
    • Power max. 200 W at 300 Ω
    • Crest factor: 2.4 at 300 Ω
    • Voltage: 2,700 Vpp
  • Forced Prep
    • Power: max. 120 W at 200 Ω
    • Crest factor: 4.9 at 200 Ω
    • Voltage: 3,900 Vpp
  • Endo Mode
    • Power: max. 100 W at 200 Ω
    • Crest factor: 1.6 at 200 Ω
    • Voltage: 2,800 Vpp
  • Contact coagulation
    • Power: max. 250 W at 200 Ω
    • Crest factor: 3.4 at 200 Ω
    • Voltage: 3,200 Vpp
  • Spray coagulation
    • Power: max. 120 W at 300 Ω
    • Crest factor: 5.6 at 300 Ω
    • Voltage: 9,000 Vpp
  • Bipolar coagulation
    • Power: max. 100 W at 100 Ω
    • Crest factor: 2.1 at 100 Ω
    • Voltage: 600 Vpp
  • Duty type: intermittent 10 s / 30 s = duty factor of 25%
  • Line fuses:
  • 220–240 V: T 4 A (slow-blow)
  • 100–127 V: T 8 A (slow-blow)
  • Sound level:
  • HF current activation:
  • 40 – 65 dB (adjustable)
  • Alarm: 65 dB(A)
  • Weight: 6 kg
  • Interference suppression:
  • Limits in conformity with EN 55011
  • Interference immunity in conformity with IEC 801
  • Dimensions
  • Width: 405 mm; height: 135 mm; depth: 380 mm
  • CE-marking according to 93/42/EEC

Accessories for  electrosurgery

Accessories for all diciplines

  • Monopolar electrode handles
  • Monopolar electrodes
  • Neutral electrodes
  • Bipolar instruments
  • Instruments for bipolar vessel sealing
  • Monopolar and bipolar connecting cables and adapters
  • KLS Martin Argon Beamer System (MABS)
  • marVAC smoke evacuator and accessories
  • NervScout Nerve Stimulator
  • Foot switches
  • Trolleys