MANUFACTURER : HAMILTON MEDICAL AG
PRODUCT CATEGORY :

The next generation of intelligent ICU ventilators

  • Independent air supply
  • State-of-the-art ventilation modes for adult, pediatric and neonatal patients
  • Adaptive, lung-protective ventilation modes ASV® and INTELLiVENT®-ASV
  • P/V Tool Pro for lung assessment and recruitment
  • Transpulmonary pressure measurement
  • High flow oxygen therapy
  • High-performance non-invasive ventilation
DETAILED DESCRIPTION
TECHNICAL SPECIFICATIONS
ACCESSORIES
RELATED FILES
VIDEO

With the new HAMILTON C6, Hamilton Medical, expands its portfolio in the high-end ventilation segment and ushers in the next generation of intelligent and versatile ICU ventilators for all patient population.

The HAMILTON C6 represents a new generation of high-end ventilators. The combination of modularity, ease of use, mobility, and advanced features allows clinicians to ensure an individualized, lung-protective ventilation therapy for all patient populations.

The HAMILTON C6 continuous the tradition of its predecessors and comes packed with Intelligent Ventilation technologies. Apart from the advanced ventilation modes ASV® and INTELLiVENT®-ASV, the HAMILTON C6 offers tools for lung assessment and recruitment maneuvers, continuous cuff pressure management, transpulmonary pressure measurement, state-of-the-art ventilation monitoring and an integrated humidifier control.

With this new ventilator, Hamilton Medical also introduces the brand-new technology IntelliSync+. It was developed to avoid patient-ventilator asynchronies and their negative effects on patients. By continuously analyzing waveform shapes at least hundred times per second, IntelliSync+ detects patient efforts and cycling immediately, and initiates inspiration and expiration in real-time. This is achieved regardless of the ventilation mode and without additional hardware.

The HAMILTON C6 comes equipped with a high-performance turbine with life-long warranty, providing a class-leading peak flow of 260 liters per minute. Together with a slender and easy maneuverable trolley and a 3-hour battery life, the HAMILTON C6 thus can effortlessly accompany patients on transports within the hospital.

The HAMILTON-C6 offers:

  • Adult, pediatric and neonatal ventilation.
  • Independence from air supply with integrated ultra-quiet turbine (lifetime warranty)
  • Over 3 hours of battery operating time
  • Automated control of the patient’s ventilation and oxygenation with INTELLiVENT-ASV
  • Protective Ventilation tool for lung assessment and recruitment via P/V Tool Pro
  • Intelligent automated ventilation via Adaptive Support Ventilation (ASV)
  • Advanced invasive ventilation modes such as (S)CMV, SIMV, APVCMV/(S)CMV+, APVSIMV/SIMV+, PCV+, PSIMV+ & SPONT
  • Synchronized non – invasive ventilation modes such as NIV & NIV-ST
  • Bilevel ventilation modes such as DuoPAP & APRV
  • Demand-flow nCPAP & nCPAP-PS ventilation modes (optional)
  • High flow oxygen therapy
  • Adjustable resistance compensation for endotracheal tubes TRC
  • Automatic response (leak compensation) to varying leaks and adaption of trigger sensitivity in all modes by IntelliTrig
  • Inspiratory and expiratory trigger synchronization via IntelliSync+
  • Transpulmonary pressure monitoring via esophageal catheter.
  • Capnography, mainstream (volumetric) or sidestream
  • SpO2 monitoring
  • Cuff pressure controller control from ventilator IntelliCuff
  • Nebulization (pneumatic or Aerogen)
  • HAMILTON-H900 humidifier control via ventilator
  • Paramagnetic O2 sensor
  • 17in HD touch screen
  • Display of 63 monitoring parameters.
  • Real-time visualization of the lungs with representations of tidal volume, lung compliance, heart and pulse, resistance and patient activity, including hemodynamic status and cuff pressure via Dynamic lung.
  • Graphic display of target and actual parameters for tidal volume, frequency, pressure, patient activity, and minute ventilation via ASV target graphics
  • Visual representation of ventilator dependency and weaning process, grouped into oxygenation, CO2 elimination, patient activity, PetCO2, SpO2, pulse, and heart lung index (HLI) via Vent Status
  • Real-time waveforms for Pressure, Flow, Volume, Off, PCO2, FCO2, Plethysmogram1, Ptrachea, Pes, Ptranspulm
  • Loops Pressure/Volume, Pressure/Flow, Volume/Flow, Volume/PCO2, Volume/FCO2, Pes/Volume, Ptranspulm/Volume
  • Trends up to 72 hours for a selected parameter or combination of parameters
  • INTELLiVENT-ASV panels
  • Event log (up to 10,000 events with date and time stamp)
  • Integrated on-screen help for troubleshooting alarms
  • Communication ports: Three COM ports, two USB ports, DVI, Nurse call
  • Trolley with Humidifier support, cylinder holder and tubing support arm
  • Standards and approvals
  1. Classification
    1. Class IIb, continuously operating according to EC directive 93/42/EEC Certification  EN 60601-1:2006/A1:2013, IEC 60601-1-2:2014, ANSI/AAMI ES60601-1:2005/(R)2012, ISO 80601-2-12:2011, CAN/CSA-C22.2 NO. 60601-1:14, EN ISO 5356-1:2015, ISO 80601-2-55:2011
  2. Declaration
    1. The HAMILTON-C6 was developed in accordance with pertinent international standards and FDA guidelines. The ventilator is manufactured within an EN ISO 13485 and EN ISO 9001, Council Directive 93/42/EEC, Annex II, Article 3 certified quality management system. The ventilator meets the Essential Requirements of Council Directive 93/42/EEC, Annex I.
  3. Electromagnetic compatibility
    1. According to IEC 60601-1-2:2014
  4. Safety Class
    1. Class I, Type B applied part (ventilator breathing system, VBS), type BF applied parts CO2 sensor including CO2 module connector, humidifier, Aerogen§ system, nebulizer, and SpO2 sensor including SpO2 adapter, continuous operation according to IEC 60601-1

Breathing sets HAMILTON-G5_S1

Breathing circuit sets, single use

  • User-friendly as flow sensor, tube, connectors and expiratory valve set are preassembled
  • Heated (for HAMILTON-H900 humidifier) and nonheated breathing circuit sets
  • Reduced risk of Ventilator Associated Pneumonia (VAP) due to single patient use

CO2 measurement

  • Mainstream and sidestream
  • Reliable measurement
  • Comfortable fit

Expiratory valve sets

  • Specially developed for our ventilators
  • Quickly mountable and easy to use
  • High patient safety

Flow sensors

  • High accuracy of tidal volume due to proximal flow measurement
  • Specially developed and approved for use with Hamilton Medical ventilators
  • Reduced risk of Ventilator Associated Pneumonia (VAP) due to single patient usage

High flow interfaces

  • Extra soft material and comfortable fit
  • Highly flexible tube to reduce the risk of kinking
  • Elastic and flexible, 360°-adjustable headband

nCPAP interfaces for neonates

  • High patient comfort due to soft materials and low noise levels
  • Optimal fit due to the flexible connection and adjustable adapter
  • Masks and bonnets from XXS to XXL

Nebulization

  • Effective dose of delivery
  • Silent operation
  • Small particle size

NIV masks

  • Comfortable positioning due to automatic adjustment of the forehead cushion
  • Four interchangeable elbows for any clinical use
  • Color-coded cord for quick release in emergencies

Oxygen measurement

  • Reliable measurement
  • Maintenance free with paramagnetic sensor
  • For all patient groups