espa2
espa
English
BACK TO PRODUCTS
ME MB 1 ENDO
MANUFACTURER : KLS MARTIN
PRODUCT CATEGORY :
Is considered a successful classic in the field of endoscopy - the ME MB1 endo. The hallmarks of this HF unit are its straightforward operating concept and a tremendous price-performance ratio.
DETAILED DESCRIPTION
TECHNICAL SPECIFICATIONS
ACCESSORIES
RELATED FILES
VIDEO

It is not without reason that it is considered a successful classic in the field of endoscopy – the ME MB 1 endo. The hallmarks of this HF unit are its straightforward operating concept and a tremendous price-performance ratio.

CONTROL BY ENDO MODE

The special “endo” cutting mode enables a fractionated and thus controlled cut. The ME MB 1 endo is particularly well suited for low-resistance fields of use – such as papillotomy or polypectomy.

HIGH PATIENT SAFETY THANKS TO PATIENT CONTROL SYSTEM (PCS)

Our proven Patient Control System (PCS), used in conjunction with split neutral electrodes, offers reliable NE application monitoring throughout the surgical procedure. If the neutral electrode makes poor contact with the patient’s skin, an optical warning signal is immediately released and HF current activation blocked as a result.

OPTIMAL WITH THE ARGON BEAMER SYSTEM (MABS)

If used in conjunction with the MB 181 Argon Beamer System (MABS), the ME MB 1 endo offers you all the possibilities afforded by argon plasma surgery.

  • Supply voltage:
  • 220-240 V; 50-60 Hz or 100-127 V; 50-60 Hz
  • Selectable via dummy plug located inside the unit by Technical Service
  • Power input:
  • with no HF power output: approx. 16 VA
  • at max. power output: approx. 800 VA
  • Class of protection: I
  • Classified acc. to MDD: II b
  • Leakage currents LF and HF: in acc. with EN IEC 60601, Part 2-2
  • Type of equipment: CF; defibrillator-proof
  • Nominal frequency: 450 kHz
  • Pulse frequency: 30 kHz

HF OUTPUT POWER:

Type of current

  • Cutting 1:
    • Power: max. 400 W at 300 Ω
    • Crest factor: 1.6 at 300 Ω
    • Voltage: max. 2300 Vpp
  • Cutting 2:
    • Power: max. 300 W at 300 Ω
    • Crest factor: 1.9 at 300 Ω
    • Voltage: max. 2500 Vpp
  • Endo-Mode:
    • Power: max. 100 W at 200 Ω
    • Crest factor: 1.6 at 200 Ω
    • Voltage: max. 2800 Vpp
  • Contact coagulation:
    • Power: max. 250 W at 200 Ω
    • Crest factor: 3.4 at 200 Ω
    • Voltage: max. 3200 Vpp
  • Spray coagulation:
    • Power: max. 120 W at 300 Ω
    • Crest factor: 5.6 at 300 Ω
    • Voltage: max. 6000 Vpp
  • Bipolar coagulation:
    • Power: max. 100 W at 100 Ω
    • Crest factor: 2.1 at 100 Ω
    • Voltage: max. 600 Vpp
  • Duty type: intermittent INT 10 s /30 s, equivalent to a duty factor of 25%
  • Mains fuses:
  • 220-240 V: T 4 A (slow-blow.)
  • 100-127 V: T 8 A (slow-blow.)
  • Signal level:
  • HF activation: 55 dB (A) (adjustable between 50 dB and 60 dB by technical Service) Alarm: 65 dB(A)
  • Weight: 6 kg
  • Interference suppression: Limits in conformity with EN 55011, Interference immunity in conformity with IEC 801
  • Dimensions: 405 mm x 135 mm x 380 mm (W x H x D)

Accessories for  electrosurgery

Accessories for all disciplines

  • Monopolar electrode handles
  • Monopolar electrodes
  • Neutral electrodes
  • Bipolar instruments
  • Instruments for bipolar vessel sealing
  • Monopolar and bipolar connecting cables and adapters
  • KLS Martin Argon Beamer System (MABS)
  • marVAC smoke evacuator and accessories
  • NervScout Nerve Stimulator
  • Foot switches
  • Trolleys